Abstract
To define the optimal blood collection parameters for plasma human immunodeficiency virus type 1 (HIV-1) viral load testing, plasma HIV-1 RNA levels were quantitated with the NASBA HIV-1 RNA QT System from blood specimens that were collected, processed, and stored under a variety of conditions that might have affected HIV-1 RNA stability. We determined that when whole blood was processed within 2 h of specimen collection the levels of HIV-1 RNA detected in EDTA-, heparin-, and acid citrate dextrose (ACD)-anticoagulated plasma samples were comparable. The levels of HIV-1 RNA in serum specimens (mean = 4.126 log units) were significantly lower (P < 0.01) than the levels in corresponding plasma samples (mean = 4.501 log units). One cycle of freeze-thaw (-70 degrees C) did not significantly reduce the level of HIV-1 RNA detected in EDTA-, heparin-, or ACD-anticoagulated plasmas. The EDTA-anticoagulated plasmas showed the smallest decrease in HIV-1 RNA copies (0.050 log units). HIV-1 RNA levels decreased over a 6-month time period in serum as well as in EDTA-, ACD-, and heparin-anticoagulated plasmas stored at -70 degrees C. However, the only significant decreases were for serum (mean decrease = 0.317 log units) and heparin-anticoagulated samples (mean decrease = 0.384 log units). A comparison of the levels of HIV-1 RNA in cell-free plasma collected in VACUTAINER EDTA Plasma Preparation Tubes and in standard VACUTAINER EDTA tubes determined that HIV-1 RNA levels were stable for up to 30 h after collection when stored at either room temperature (mean standard deviation [SD] = +/- 0.101 log units) or at 4 degrees C (mean SD = +/- 0.102 log units) as cell-free plasma or as EDTA-anticoagulated whole blood (mean SD = +/- 0.109 log units). These data indicate that EDTA-anticoagulated plasma is the most suitable and stable matrix for HIV-1 RNA quantitation.
MeSH Terms
Anticoagulants
Blood Preservation/methods
Blood Specimen Collection/instrumentation,methods
Citric Acid
Cryopreservation/methods
Drug Stability
Edetic Acid
Glucose/analogs & derivatives
HIV Seropositivity/blood,virology
HIV-1/genetics,isolation & purification
Heparin
Humans
Indicators and Reagents
Plasma
RNA, Viral/blood
Reproducibility of Results
Viral Load/instrumentation,methods
Chemicals
Anticoagulants
Indicators and Reagents
RNA, Viral
acid citrate dextrose
Citric Acid
Heparin
Edetic Acid
Glucose
Authors & Affiliations
8 authors, click to expand affiliations / ORCID
Ginocchio C C
Department of Medicine, North Shore University Hospital, Manhasset, New York 11030, USA. cginocch@nshs.edu
Wang X P
Kaplan M H
Mulligan G
Witt D
Romano J W
Cronin M
Carroll R
References (26)
26 references, click to expand
-
Inhibition of human immunodeficiency virus gene amplification by heparin.
J Clin Microbiol. 1991 Apr;29(4):676-9
PMID: 1909709
-
Quantification of HIV-1 RNA in plasma: comparable results with the NASBA HIV-1 RNA QT and the AMPLICOR HIV monitor test.
J Acquir Immune Defic Syndr Hum Retrovirol. 1996 Oct 1;13(2):127-39
PMID: 8862277
-
Viricidal effect of polymorphonuclear leukocytes on human immunodeficiency virus-1. Role of the myeloperoxidase system.
J Clin Invest. 1992 Jun;89(6):2014-7
PMID: 1318327
-
Infectious decay of human immunodeficiency virus type 1 in plasma.
J Infect Dis. 1993 Jan;167(1):210-2
PMID: 8418169
-
Viral markers in HIV infection and AIDS.
J Acquir Immune Defic Syndr. 1993;6 Suppl 1:S32-5
PMID: 8426300
-
Measurement of HIV virus load and genotypic resistance by gene amplification in asymptomatic subjects treated with combination therapy.
J Acquir Immune Defic Syndr. 1993 Apr;6(4):366-9
PMID: 8095981
-
High levels of HIV-1 in plasma during all stages of infection determined by competitive PCR.
Science. 1993 Mar 19;259(5102):1749-54
PMID: 8096089
-
Cell-free plasma human immunodeficiency virus type 1 titer assessed by culture and immunocapture-reverse transcription-polymerase chain reaction.
J Clin Microbiol. 1993 Aug;31(8):1980-6
PMID: 8370724
-
Combination therapy with zidovudine and didanosine compared with zidovudine alone in HIV-1 infection.
Ann Intern Med. 1993 Oct 15;119(8):786-93
PMID: 8379600
-
Effect of platelet-associated virus on assays of HIV-1 in plasma.
Science. 1993 Dec 3;262(5139):1585-6
PMID: 8248811
-
Stability of infectious HIV in clinical samples and isolation from small volumes of whole blood.
J Clin Pathol. 1994 Feb;47(2):152-4
PMID: 8132829
-
The natural history of HIV-1 infection: virus load and virus phenotype independent determinants of clinical course?
Virology. 1994 Oct;204(1):223-33
PMID: 7916514
-
HIV-1 burden as a marker of disease progression and clinical response to therapy in AIDS.
Clin Lab Med. 1994 Jun;14(2):301-11
PMID: 7924193
-
Stabilities of quantitative plasma culture for human immunodeficiency virus, RNA, and p24 antigen from samples collected in VACUTAINER CPT and standard VACUTAINER tubes.
J Clin Microbiol. 1994 Sep;32(9):2212-5
PMID: 7814549
-
Viral dynamics in human immunodeficiency virus type 1 infection.
Nature. 1995 Jan 12;373(6510):117-22
PMID: 7529365
-
Rapid turnover of plasma virions and CD4 lymphocytes in HIV-1 infection.
Nature. 1995 Jan 12;373(6510):123-6
PMID: 7816094
-
A one-tube quantitative HIV-1 RNA NASBA nucleic acid amplification assay using electrochemiluminescent (ECL) labelled probes.
J Virol Methods. 1994 Sep;49(2):157-67
PMID: 7822457
-
Quantitation of HIV-1 RNA in plasma predicts outcome after seroconversion.
Ann Intern Med. 1995 Apr 15;122(8):573-9
PMID: 7887550
-
Rapid and precise quantification of HIV-1 RNA in plasma using a branched DNA signal amplification assay.
J Acquir Immune Defic Syndr Hum Retrovirol. 1995 Apr 15;8(5):446-54
PMID: 7697440
-
Quantitative molecular monitoring of human immunodeficiency virus type 1 activity during therapy with specific antiretroviral compounds.
J Clin Microbiol. 1995 Jan;33(1):16-23
PMID: 7699034
-
Predictors for non- and slow progression in human immunodeficiency virus (HIV) type 1 infection: low viral RNA copy numbers in serum and maintenance of high HIV-1 p24-specific but not V3-specific antibody levels.
J Infect Dis. 1995 Apr;171(4):811-21
PMID: 7706807
-
Comparative stabilities of quantitative human immunodeficiency virus RNA in plasma from samples collected in VACUTAINER CPT, VACUTAINER PPT, and standard VACUTAINER tubes.
J Clin Microbiol. 1995 Jun;33(6):1562-6
PMID: 7650187
-
The one-tube quantitative HIV-1 RNA NASBA: precision, accuracy, and application.
PCR Methods Appl. 1995 Feb;4(4):S177-84
PMID: 8574186
-
Changes in plasma HIV-1 RNA and CD4+ lymphocyte counts and the risk of progression to AIDS. Veterans Affairs Cooperative Study Group on AIDS.
N Engl J Med. 1996 Feb 15;334(7):426-31
PMID: 8552144
-
Association of plasma human immunodeficiency virus type 1 RNA level with risk of clinical progression in patients with advanced infection. AIDS Clinical Trials Group (ACTG) 116B/117 Study Team. ACTG Virology Committee Resistance and HIV-1 RNA Working Groups.
J Infect Dis. 1996 Oct;174(4):704-12
PMID: 8843206
-
Reduction in plasma human immunodeficiency virus ribonucleic acid after dideoxynucleoside therapy as determined by the polymerase chain reaction.
J Clin Invest. 1991 Nov;88(5):1755-9
PMID: 1682345