Home LiteratureArticle Details
PMID: 7814549 Published · ppublish English Comparative Study Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S.

Stabilities of quantitative plasma culture for human immunodeficiency virus, RNA, and p24 antigen from samples collected in VACUTAINER CPT and standard VACUTAINER tubes.

Journal of clinical microbiology ·Vol. 32 ·No. 9 ·1994-09-00 ·Pages 2212-5

Mole L, Margolis D, Carroll R, Todd J, Holodniy M

Abstract

We evaluated the stability of human immunodeficiency virus (HIV) load markers from blood samples collected in VACUTAINER CPT or standard VACUTAINER brand tubes using sodium heparin or sodium citrate as anticoagulants. Quantitative plasma culture and p24 antigen concentrations were determined, and HIV RNA levels in plasma were measured by both reverse transcription-PCR-enzyme-linked immunosorbent assay (RT-PCR-ELISA) and branched DNA methods. All tubes were stored at room temperature for analysis at 2, 24, 48, and 72 h after the blood samples were drawn. No difference was seen between tube types with respect to the HIV titer in plasma or the positivity rate for all samples that demonstrated a fall in titer over time. Unbound p24 antigen levels in plasma decreased during the initial 48-h period in both tube types. Immune complex-dissociated p24 antigen levels decreased in CPT tubes but not in standard VACUTAINER tubes. The HIV RNA copy number in plasma measured by RT-PCR-ELISA was stable in most subjects and was significantly higher in CPT tubes than in standard VACUTAINER tubes at 24 and 72 h after the blood samples were drawn. The branched DNA probe assay detected a significant decline in HIV RNA equivalent in plasma over 72 h in both collection tubes, the decline being more dramatic in the standard VACUTAINER tube than the CPT tube. Overall, interday variability suggests that samples collected for a particular assay should be processed at the same time after blood is drawn and that a particular tube type be used throughout a given study.

MeSH Terms
Anticoagulants Blood Specimen Collection/instrumentation CD4 Lymphocyte Count Culture Media DNA, Viral/blood Didanosine/therapeutic use Drug Therapy, Combination Enzyme-Linked Immunosorbent Assay Evaluation Studies as Topic False Negative Reactions Gels HIV Core Protein p24/isolation & purification HIV Infections/blood,drug therapy,microbiology HIV-1/growth & development,isolation & purification Humans Polyesters Polymerase Chain Reaction Predictive Value of Tests RNA, Viral/isolation & purification Severity of Illness Index Specimen Handling Viremia/microbiology Virus Cultivation Zidovudine/therapeutic use
Chemicals
Anticoagulants Culture Media DNA, Viral Gels HIV Core Protein p24 Polyesters RNA, Viral Zidovudine Didanosine
Authors & Affiliations
5 authors, click to expand affiliations / ORCID
Mole L
ARC-AIDS Research Center, Veterans Affairs Medical Center, Palo Alto, California 94304.
Margolis D
Carroll R
Todd J
Holodniy M
References (10)
10 references, click to expand
  1. Quantitation of human immunodeficiency virus type 1 in the blood of infected persons.
    N Engl J Med. 1989 Dec 14;321(24):1621-5 PMID: 2586564
  2. Reduction in plasma human immunodeficiency virus ribonucleic acid after dideoxynucleoside therapy as determined by the polymerase chain reaction.
    J Clin Invest. 1991 Nov;88(5):1755-9 PMID: 1682345
  3. Viricidal effect of polymorphonuclear leukocytes on human immunodeficiency virus-1. Role of the myeloperoxidase system.
    J Clin Invest. 1992 Jun;89(6):2014-7 PMID: 1318327
  4. Infectious decay of human immunodeficiency virus type 1 in plasma.
    J Infect Dis. 1993 Jan;167(1):210-2 PMID: 8418169
  5. Diurnal and short-term stability of HIV virus load as measured by gene amplification.
    J Acquir Immune Defic Syndr. 1994 Apr;7(4):363-8 PMID: 7907661
  6. Loss of infectivity ex vivo in plasma of human immunodeficiency virus-infected patients correlates with a high CD4 cell count.
    J Infect Dis. 1993 Nov;168(5):1269-72 PMID: 7901290
  7. Effect of platelet-associated virus on assays of HIV-1 in plasma.
    Science. 1993 Dec 3;262(5139):1585-6 PMID: 8248811
  8. Use of virologic assays for detection of human immunodeficiency virus in clinical trials: recommendations of the AIDS Clinical Trials Group Virology Committee.
    J Clin Microbiol. 1993 Oct;31(10):2557-64 PMID: 8253949
  9. Quantitative evaluation of hepatitis C virus RNA in patients with concurrent human immunodeficiency virus infections.
    J Clin Microbiol. 1993 Oct;31(10):2679-82 PMID: 8253965
  10. Cell-free plasma human immunodeficiency virus type 1 titer assessed by culture and immunocapture-reverse transcription-polymerase chain reaction.
    J Clin Microbiol. 1993 Aug;31(8):1980-6 PMID: 8370724
Article Info
Journal
Journal of clinical microbiology
Abbr.
J Clin Microbiol
ISSN
0095-1137
Published
1994-09-00
Pages
2212-5
Language
English
Region
United States
NLM ID
7505564
PMCID
PMC263969
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com