Abstract
Nicotinic acetylcholine channels show bursts of activity where open channel currents are separated from each other by short closed periods called flickers. These flickers presumably represent transitions from the open state to the state preceding the first opening of a burst (doubly liganded, closed state). Using tissue cultured chick pectoral muscle, we have examined the amplitude distribution of flickers. Of those events sufficiently long to permit accurate measurement of the amplitude (approximately 25% of all flickers), approximately two-thirds had a mean current equal to 10% of the fully open channel. The remaining one-third did appear to close completely. The subconducting flicker state is not a requisite step preceding channel opening. We conclude that there are three types of flicker events: a short event (time constant approximately 0.1 ms) whose current distribution is uncertain and two longer events (time constant approximately 1 ms), one of which has a current approximately 10% of the main open state and the other of which has a current indistinguishable from zero. In contrast, the amplitude of flickers induced by the local anesthetic QX-222 is indistinguishable from zero.
MeSH Terms
Animals
Chick Embryo
Electric Conductivity
Electric Stimulation
Ion Channels/physiology
Kinetics
Mathematics
Models, Biological
Muscles/physiology
Receptors, Cholinergic/physiology
Receptors, Nicotinic/physiology
Chemicals
Ion Channels
Receptors, Cholinergic
Receptors, Nicotinic
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Auerbach A
Sachs F
References (18)
18 references, click to expand
-
Relaxation and fluctuations of membrane currents that flow through drug-operated channels.
Proc R Soc Lond B Biol Sci. 1977 Nov 14;199(1135):231-62
PMID: 22856
-
Interaction at end-plate receptors between different choline derivatives.
Proc R Soc Lond B Biol Sci. 1957 May 7;146(924):369-81
PMID: 13431862
-
Determination of dose-response curves by quantitative ionophoresis at the frog neuromuscular junction.
J Physiol. 1978 Aug;281:395-419
PMID: 309003
-
An analysis of the dose-response relationship at voltage-clamped frog neuromuscular junctions.
J Physiol. 1978 Aug;281:421-44
PMID: 309004
-
Single ionic channels observed in tissue-cultured muscle.
Nature. 1979 Dec 20-27;282(5741):861-3
PMID: 514365
-
Voltage-dependent channels in planar lipid bilayer membranes.
Physiol Rev. 1981 Jan;61(1):77-150
PMID: 6258181
-
On the stochastic properties of single ion channels.
Proc R Soc Lond B Biol Sci. 1981 Mar 6;211(1183):205-35
PMID: 6111797
-
Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches.
Pflugers Arch. 1981 Aug;391(2):85-100
PMID: 6270629
-
Gramicidin forms multi-state rectifying channels.
Nature. 1981 Nov 26;294(5839):371-3
PMID: 6171731
-
Multiple conductance states of single acetylcholine receptor channels in embryonic muscle cells.
Nature. 1981 Dec 3;294(5840):462-4
PMID: 6273742
-
Fluctuations in the microsecond time range of the current through single acetylcholine receptor ion channels.
Nature. 1981 Dec 3;294(5840):464-6
PMID: 6273743
-
Structure and function of an acetylcholine receptor.
Biophys J. 1982 Jan;37(1):371-83
PMID: 7055628
-
Rapid kinetics of single glutamate-receptor channels.
Nature. 1982 Feb 4;295(5848):410-2
PMID: 6276768
-
The kinetics of local anesthetic blockade of end-plate channels.
Biophys J. 1982 Mar;37(3):625-31
PMID: 6978739
-
Curare can open and block ionic channels associated with cholinergic receptors.
Nature. 1982 Jul 15;298(5871):272-5
PMID: 6283380
-
Acetylcholine receptor kinetics. A description from single-channel currents at snake neuromuscular junctions.
Biophys J. 1982 Sep;39(3):253-61
PMID: 6291654
-
The automated analysis of data from single ionic channels.
Pflugers Arch. 1982 Dec;395(4):331-40
PMID: 6296760
-
Local anaesthetics transiently block currents through single acetylcholine-receptor channels.
J Physiol. 1978 Apr;277:153-76