Saturable binding of cyclosporin A to erythrocytes: estimation of binding parameters in renal transplant patients and implications for bioavailability assessment.

Pharmaceutical research ·Vol. 5 ·No. 2 ·1988-02-00 ·Pages 80-5

Legg B, Rowland M

Abstract

Cyclosporin (CyA) exhibits saturable binding to erythrocytes. A one-site binding model was fitted to data from renal transplant patients receiving CyA therapy. The average maximum binding capacity is 2560 micrograms CyA/liter of packed erythrocytes; the unbound CyA concentration associated with 50% saturation of the binding site is 67 micrograms/liter. Analysis indicates that whole-blood CyA measurement to monitor drug therapy should be viewed cautiously, particularly when the hematocrit varies considerably. The error in estimating absolute bioavailability at steady state from whole-blood measurements, resulting as a consequence of the saturable binding, has been explored. Although extrapolation to the therapeutic situation, which involves transient drug administration, is difficult, errors of up to 25% are anticipated. When an accurate estimate of bioavailability is required, analysis based on plasma data is proposed. For bioequivalence testing, both blood and plasma CyA data are equally acceptable.

MeSH Terms
Binding, Competitive Biological Availability Cyclosporins/blood,pharmacokinetics Erythrocytes/metabolism Humans Kidney Transplantation
Chemicals
Cyclosporins
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Legg B
Department of Pharmacy, University of Manchester, England.
Rowland M
References (17)
17 references, click to expand
  1. Individualization of cyclosporine therapy using pharmacokinetic and pharmacodynamic parameters.
    Transplantation. 1985 Nov;40(5):457-76 PMID: 3904087
  2. The pharmacokinetics of cyclosporine A in uremic patients.
    Transplant Proc. 1986 Dec;18(6 Suppl 5):144-52 PMID: 3787709
  3. Measuring cyclosporin in plasma.
    Lancet. 1983 Apr 2;1(8327):762 PMID: 6132101
  4. A radioimmunoassay to measure cyclosporin A in plasma and serum samples.
    J Immunoassay. 1981;2(1):19-32 PMID: 7287910
  5. Role of lipoproteins and erythrocytes in the in vitro binding and distribution of cyclosporin A in the blood.
    J Pharm Pharmacol. 1982 Nov;34(11):715-8 PMID: 6129301
  6. Cyclosporine serum concentrations soon after heart or heart-lung transplantation.
    J Clin Pharmacol. 1986 Nov-Dec;26(8):652-7 PMID: 3098805
  7. The pharmacokinetics of cyclosporine. II. Blood plasma distribution and binding studies.
    Drug Metab Dispos. 1985 Mar-Apr;13(2):133-8 PMID: 2859158
  8. Disposition of cyclosporine in several animal species and man. I. Structural elucidation of its metabolites.
    Drug Metab Dispos. 1984 Jan-Feb;12(1):120-6 PMID: 6141902
  9. Simplified liquid-chromotographic analysis for cyclosporin A, and comparison with radioimmunoassay.
    Clin Chem. 1983 Jan;29(1):180-3 PMID: 6336679
  10. Intravenous cyclosporine kinetics in renal failure.
    Clin Pharmacol Ther. 1983 Nov;34(5):638-43 PMID: 6627824
  11. Cyclosporin concentrations in whole blood and plasma.
    Clin Chem. 1984 May;30(5):817 PMID: 6713654
  12. Cyclosporin: measurement of fraction unbound in plasma.
    J Pharm Pharmacol. 1987 Aug;39(8):599-603 PMID: 2888849
  13. Therapeutic drug monitoring of cyclosporine.
    Mayo Clin Proc. 1984 Aug;59(8):571-2 PMID: 6379321
  14. Clearance concepts in pharmacokinetics.
    J Pharmacokinet Biopharm. 1973 Apr;1(2):123-36 PMID: 4764426
  15. Clinical pharmacokinetics of cyclosporin.
    Clin Pharmacokinet. 1986 Mar-Apr;11(2):107-32 PMID: 3514043
  16. Evidence of a cyclosporine-binding protein in human erythrocytes.
    Transplantation. 1986 Dec;42(6):627-32 PMID: 3538549
  17. THE ESTIMATION OF HEPATIC BLOOD FLOW IN MAN.
    J Clin Invest. 1945 Nov;24(6):890-7 PMID: 16695286
Article Info
Journal
Pharmaceutical research
Abbr.
Pharm Res
ISSN
0724-8741
Published
1988-02-00
Pages
80-5
Language
English
Region
United States
NLM ID
8406521
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com