Home LiteratureArticle Details
PMID: 9825328 Published · ppublish English Clinical Trial Journal Article Multicenter Study

Multisite pacing as a supplemental treatment of congestive heart failure: preliminary results of the Medtronic Inc. InSync Study.

Pacing and clinical electrophysiology : PACE ·Vol. 21 ·No. 11 Pt 2 ·1998-11-00 ·Pages 2249-55

Gras D, Mabo P, Tang T, Luttikuis O, Chatoor R, Pedersen AK, Tscheliessnigg HH, Deharo JC, Puglisi A, Silvestre J, Kimber S, Ross H, Ravazzi A, Paul V, Skehan D

Abstract

This report describes the initial results of the "InSync" study, a European and Canadian multicenter trial that examines the safety and efficacy of a multisite pacemaker (Medtronic InSync) and of left ventricular pacing leads (Medtronic 2187 and 2188) implanted via a cardiac vein as a supplemental treatment of refractory congestive heart failure. Over a 10-month period, the system was implanted successfully in 68 of the 81 (84%) patients who had been enrolled in the study. The 68 patients were, on average, 66 +/- 10 years old, had a mean left ventricular ejection fraction (LVEF) = 21% +/- 9%, and 63% were in NYHA functional Class III and 37% were in Class IV. No system implant related complication occurred. During follow-up, 7 of 10 patients who exited the study had died, 4 suddenly. There was a clinical benefit among surviving patients, which was corroborated by a significant improvement in NYHA functional class and in the Minnesota Living with Heart Failure Quality of Life Questionnaire Score (MLS) and by a longer distance covered during a 6-minute walk test. This clinical improvement was associated with a significant narrowing of the paced QRS complex during biventricular pacing, a significant decrease in the interventricular mechanical delay, and a trend towards an increase in the duration of ventricular filling. These encouraging preliminary results confirm the feasibility and reliability of this new multisite pacing system in the management of dilated cardiomyopathy and support the continuation of further evaluations of this complementary treatment of refractory congestive heart failure.

MeSH Terms
Aged Cardiac Pacing, Artificial/methods Cardiomyopathy, Dilated/therapy Electrocardiography Electrodes, Implanted Equipment Design Feasibility Studies Female Follow-Up Studies Heart Failure/therapy Humans Male Pacemaker, Artificial Time Factors
Authors & Affiliations
15 authors, click to expand affiliations / ORCID
Gras D
Centre Chirurgical du Val d'Or, Saint-Cloud, France.
Mabo P
Tang T
Luttikuis O
Chatoor R
Pedersen A K
Tscheliessnigg H H
Deharo J C
Puglisi A
Silvestre J
Kimber S
Ross H
Ravazzi A
Paul V
Skehan D
Article Info
Journal
Pacing and clinical electrophysiology : PACE
Abbr.
Pacing Clin Electrophysiol
ISSN
0147-8389
Published
1998-11-00
Pages
2249-55
Language
English
Region
United States
NLM ID
7803944
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com