Home LiteratureArticle Details
PMID: 9638943 Published · ppublish English Journal Article

Rapid identification of comigrating gel-isolated proteins by ion trap-mass spectrometry.

Electrophoresis ·Vol. 19 ·No. 6 ·1998-05-00 ·Pages 968-80

Arnott D, Henzel WJ, Stults JT

Abstract

In the search for novel nuclear binding proteins, two bands from a sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) gel were analyzed and each was found to contain a number of proteins that subsequently were identified by tandem mass spectrometry (MS/MS) on a quadrupole ion trap instrument. The bands were digested with trypsin in situ on a polyvinylidene difluoride (PVDF) membrane following electroblot transfer. Analysis of a 2.5% aliquot of each peptide mixture by matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) followed by an initial database search with the peptide masses failed to identify the proteins. The peptides were separated by reversed-phase capillary high performance liquid chromatography (HPLC) in anticipation of subsequent Edman degradation, but mass analysis of the chromatographic fractions by MALDI-MS revealed multiple, coeluting peptides that precluded this approach. Selected fractions were analyzed by capillary HPLC-electrospray ionization-ion trap mass spectrometry. Tandem mass spectrometry provided significant fragmentation from which full or partial sequence was deduced for a number of peptides. Two stages of fragmentation (MS3) were used in one case to determine additional sequence. Database searches, each using a single peptide mass plus partial sequence, identified four proteins from a single electrophoretic band at 45 kDa, and four proteins from a second band at 60 kDa. Many of these proteins were derived from human keratin. The protein identifications were corroborated by the presence of multiple matching peptide masses in the MALDI-MS spectra. In addition, a novel sequence, not found in protein or DNA databases, was determined by interpretation of the MS/MS data. These results demonstrate the power of the quadrupole ion trap for the identification of multiple proteins in a mixture, and for de novo determination of peptide sequence. Reanalysis of the fragmentation data with a modified database searching algorithm showed that the same sets of proteins were identified from a limited number of fragment ion masses, in the absence of mass spectral interpretation or amino acid sequence. The implications for protein identification solely from fragment ion masses are discussed, including advantages for low signal levels, for a reduction of the necessary interpretation expertise, and for increased speed.

MeSH Terms
Amino Acid Sequence Chromatography, High Pressure Liquid/methods DNA-Binding Proteins/isolation & purification Databases, Factual Gels HeLa Cells Humans Keratins/isolation & purification Mass Spectrometry/instrumentation,methods Molecular Sequence Data Nuclear Proteins/isolation & purification Peptide Fragments/isolation & purification Peptide Mapping/methods Proteins/isolation & purification
Chemicals
DNA-Binding Proteins Gels Nuclear Proteins Peptide Fragments Proteins Keratins
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Arnott D
Protein Chemistry Department, Genetech, Inc., South San Francisco, CA 94080, USA.
Henzel W J
Stults J T
Article Info
Journal
Electrophoresis
Abbr.
Electrophoresis
ISSN
0173-0835
Published
1998-05-00
Pages
968-80
Language
English
Region
Germany
NLM ID
8204476
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com