Home LiteratureArticle Details
PMID: 8222076 Published · ppublish English Journal Article Research Support, Non-U.S. Gov't

Assessment of smooth muscle contribution to descending thoracic aortic elastic mechanics in conscious dogs.

Circulation research ·Vol. 73 ·No. 6 ·1993-12-00 ·Pages 1040-50

Barra JG, Armentano RL, Levenson J, Fischer EI, Pichel RH, Simon A

Abstract

Early investigators found contradictory evidence that vascular smooth muscle activation reduces the elastic modulus of the arterial wall under isotonic conditions but increases it under isometric conditions, concomitant with increased pulse-wave velocity. We examined the individual contributions of aortic constituents to the elastic modulus of the aortic wall to determine if isobaric analysis produces an accurate assessment of vascular smooth muscle activation. We used a modified Maxwell model assuming an incremental elastic modulus (Einc) composed of the elastic modulus of elastin fibers (EE), the elastic modulus of collagen fibers (EC) affected by the fraction of collagen fibers (fC) recruited to support wall stress, and the elastic modulus of the vascular smooth muscle (ESM) according to the following formula: Einc = EE+EC x fC+ESM.Einc was assessed in eight conscious dogs using descending thoracic aortic pressure (microtransducer) and diameter (sonomicrometry) measurements. Stress-strain relations in the control state and during activation of smooth muscle by continuous administration of phenylephrine (5 micrograms.kg-1 x min-1) were obtained by transient occlusions of the descending aorta and inferior vena cava. Results were as follows: EE was 4.99 +/- 1.58 x 10(6) dynes/cm2 (mean +/- SD), and EC was 965.8 +/- 399.8 x 10(6) dynes/cm2, assessed during the control state. Phenylephrine administration increased the theoretical pulse-wave velocity (Moens-Korteweg equation) from 5.25 +/- 1.03 m/s during the control state to 7.57 +/- 2.53 m/s (P < .005). Active muscle exhibited a unimodal stress-strain curve with a maximum stress of 0.949 +/- 0.57 x 10(6) dynes/cm2 at a corresponding strain value of 1.299 +/- 0.083. The maximum value observed corresponded, on the pressure-diameter curve of the active artery, to a pressure of 234.28 +/- 46.6 mm Hg and a diameter of 17.94 +/- 1.6 mm. The maximum ESM derived from the stress-strain relation of the active muscle was 8.345 +/- 7.56 x 10(6) dynes/cm2 at a strain value of 1.283 +/- 0.079. This point was located at 208.01 +/- 40.8 mm Hg and 17.73 +/- 1.41 mm on the active pressure-diameter curve. During activation of vascular smooth muscle, Einc decreased (P < .05) when plotted against internal pressure but increased (P < .05) when plotted against strain, over the operative range.(ABSTRACT TRUNCATED AT 400 WORDS)

MeSH Terms
Animals Aorta, Thoracic/drug effects,physiology Dogs Elasticity Hemodynamics/drug effects Homeostasis Male Models, Cardiovascular Muscle, Smooth, Vascular/drug effects,physiology Phenylephrine/pharmacology Stress, Mechanical
Chemicals
Phenylephrine
Authors & Affiliations
6 authors, click to expand affiliations / ORCID
Barra J G
Research and Teaching Department, Favaloro Foundation, Buenos Aires, Argentina.
Armentano R L
Levenson J
Fischer E I
Pichel R H
Simon A
Article Info
Journal
Circulation research
Abbr.
Circ Res
ISSN
0009-7330
Published
1993-12-00
Pages
1040-50
Language
English
Region
United States
NLM ID
0047103
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com