Voltage clamp of cardiac muscle. A theoretical analysis of early currents in the single sucrose gap.

Biophysical journal ·Vol. 12 ·No. 11 ·1972-11-00 ·Pages 1496-508

Kootsey JM, Johnson EA

Abstract

A theoretical model is presented for the early currents in the voltage clamp of cardiac muscle using the single sucrose gap technique. The preparation is represented by a single one-dimensional active cable with modified Hodgkin-Huxley membrane and the interent imperfections in the technique are also included, e.g., leakage through the sucrose gap and resistance in series with the membrane in the test compartment. The stability of the control system was found to depend on the position of the control point with respect to the sucrose gap border. Computed currents for a stable system closely resembled those in the literature and those from a near-ideal system (e.g., squid axon.) The potential immediately across the membrane, however (not including potential drops across the series resistance external to the membrane), was found to be essentially uncontrolled and the "current-voltage" relationship was shown to be almost independent of membrane properties.

MeSH Terms
Action Potentials Electric Conductivity Electrophysiology Heart/physiology Kinetics Mathematics Membrane Potentials Models, Biological Sucrose
Chemicals
Sucrose
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Kootsey J M
Johnson E A
References (8)
8 references, click to expand
  1. Computed action potentials for Purkinje fiber membranes with resistance and capacitance in series.
    Biophys J. 1968 Aug;8(8):951-64 PMID: 5661902
  2. Capacitance of the surface and transverse tubular membrane of frog sartorius muscle fibers.
    J Gen Physiol. 1969 Mar;53(3):265-78 PMID: 5767332
  3. Two components of inward current in myocardial muscle fibers.
    Pflugers Arch. 1969;307(3):190-203 PMID: 5813636
  4. The slow inward current and the action of manganese ions in guinea-pig's myocardium.
    Pflugers Arch. 1970;316(1):81-94 PMID: 5461402
  5. A quantitative description of membrane current and its application to conduction and excitation in nerve.
    J Physiol. 1952 Aug;117(4):500-44 PMID: 12991237
  6. The effect of the cardiac membrane potential on the rapid availability of the sodium-carrying system.
    J Physiol. 1955 Jan 28;127(1):213-24 PMID: 14354640
  7. Analysis of certain errors in squid axon voltage clamp measurements.
    Biophys J. 1960 Nov;1:161-202 PMID: 13775643
  8. Theoretical stability properties of a space-clamped axon.
    Biophys J. 1962 Mar;2:105-27 PMID: 13878047
Article Info
Journal
Biophysical journal
Abbr.
Biophys J
ISSN
0006-3495
Published
1972-11-00
Pages
1496-508
Language
English
Region
United States
NLM ID
0370626
PMCID
PMC1484190
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com