Home LiteratureArticle Details
PMID: 380857 Published · ppublish English Comparative Study Journal Article

Circulating immune complexes in serum from patients with dengue haemorrhagic fever.

Clinical and experimental immunology ·Vol. 36 ·No. 1 ·1979-04-00 ·Pages 46-53

Ruangjirachuporn W, Boonpucknavig S, Nimmanitya S

Abstract

Circulating immune complexes were detectable in 80% of serum from patients with dengue haemorrhagic fever. The immune complexes were detected for the first time on day two after the onset of the fever. The amount of complexes reached the maximum value on day 4 or 5 after onset, or when the patients developed shock or subsidence of fever, after which the complexes decreased in number. The number of complexes also correlated well with the clinical grading (severity) of the disease, i.e. the maximum amount was shown in grade III. These complexes may play a part in the pathogenesis of this disease.

MeSH Terms
Adolescent Antigen-Antibody Complex Child Child, Preschool Dengue/complications,immunology Fluorescent Antibody Technique Humans Latex Fixation Tests Shock/complications,immunology Time Factors
Chemicals
Antigen-Antibody Complex
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Ruangjirachuporn W
Boonpucknavig S
Nimmanitya S
References (25)
25 references, click to expand
  1. Separation of univalent fragments from the bivalent rabbit antibody molecule by reduction of disulfide bonds.
    Arch Biochem Biophys. 1960 Aug;89:230-44 PMID: 14427334
  2. A simple chromatographic method for preparation of gamma globulin.
    Proc Soc Exp Biol Med. 1960 Jan;103:250-2 PMID: 14416397
  3. CYTOLOGY OF BURKITT'S TUMOUR (AFRICAN LYMPHOMA).
    Lancet. 1964 Feb 1;1(7327):238-40 PMID: 14086209
  4. Techniques for hemagglutination and hemagglutination-inhibition with arthropod-borne viruses.
    Am J Trop Med Hyg. 1958 Sep;7(5):561-73 PMID: 13571577
  5. The latex fixation test. I. Application to the serologic diagnosis of rheumatoid arthritis.
    Am J Med. 1956 Dec;21(6):888-92 PMID: 13372565
  6. Immunofluorescent staining of the surfaces of lymphocytes in suspension from patients with dengue hemorrhagic fever.
    Am J Pathol. 1976 Oct;85(1):37-48 PMID: 61729
  7. Quantitation of immune complexes by competitive inhibition of binding of Clq to insoluble IgG aggregates.
    J Immunol Methods. 1977;15(1):39-45 PMID: 845441
  8. Binding of soluble immune complexes to human lymphoblastoid cells. I. Characterization of receptors for IgG Fc and complement and description of the binding mechanism.
    J Exp Med. 1974 Oct 1;140(4):877-94 PMID: 4139225
  9. Binding of soluble immune complexes to human lymphoblastoid cells. II. Use of Raji cells to detect circulating immune complexes in animal and human sera.
    J Exp Med. 1974 Nov 1;140(5):1230-44 PMID: 4138539
  10. Recurrence of epidemic dengue hemorrhagic fever in an insular setting.
    Am J Trop Med Hyg. 1969 Jul;18(4):573-9 PMID: 5795449
  11. Rabbit C1q: purification, functional and structural studies.
    J Immunol Methods. 1972 Nov;2(1):25-34 PMID: 4139208
  12. Anti-dengue immunoglobulins and serum beta 1 c-a globulin levels in dengue shock syndrome.
    J Immunol. 1969 Feb;102(2):412-20 PMID: 4180121
  13. Precipitin reactions of the C1q component of complement with aggregated gamma-globulin and immune complexes in gel diffusion.
    Immunology. 1970 Dec;19(6):909-19 PMID: 4098878
  14. Immune complex disease in experimental animals and man.
    Adv Immunol. 1973;16(0):185-264 PMID: 4599389
  15. The Raji cell radioimmune assay for detecting immune complexes in human sera.
    J Clin Invest. 1976 Jan;57(1):169-82 PMID: 128562
  16. Circulating immune complexes in the serum in systemic lupus erythematosus and in carriers of hepatitis B antigen. Quantitation by binding to radiolabeled C1q.
    J Clin Invest. 1974 Aug;54(2):297-309 PMID: 4847246
  17. The potential pathogenic role of complement in dengue hemorrhagic shock syndrome.
    N Engl J Med. 1973 Nov 8;289(19):996-1000 PMID: 4742219
  18. C1g precipitins in the sera of patients with systemic lupus erythematosus and other hypocomplementemic states: characterization of high and low molecular weight types.
    J Exp Med. 1971 Sep 1;134(3 Pt 2):228s-241s PMID: 4998931
  19. A simple method for the determination of complement receptor-bearing mononuclear cells.
    J Immunol. 1976 Mar;116(3):595-9 PMID: 815430
  20. Glomerular changes in dengue hemorrhagic fever.
    Arch Pathol Lab Med. 1976 Apr;100(4):206-12 PMID: 786215
  21. C1q deviation test for the detection of immune complexes, aggregates of IgG, and bacterial products in human serum.
    J Exp Med. 1975 Jul 1;142(1):139-50 PMID: 1097571
  22. Indirect fluorescent antibody technic for demonstration of serum antibody in dengue hemorrhagic fever cases.
    Am J Clin Pathol. 1975 Sep;64(3):365-71 PMID: 1099896
  23. Detection of circulating antigen-antibody complexes by their inhibitory effect on the agglutination of IgG-coated particles by rheumatioid factor of Clq.
    Clin Exp Immunol. 1976 Aug;25(2):212-26 PMID: 954232
  24. Measles infection. Involvement of the complement system.
    Clin Exp Immunol. 1976 Jun;24(3):401-6 PMID: 939047
  25. Dengue and chikungunya virus infection in man in Thailand, 1962-1964. I. Observations on hospitalized patients with hemorrhagic fever.
    Am J Trop Med Hyg. 1969 Nov;18(6):954-71 PMID: 5355242
Article Info
Journal
Clinical and experimental immunology
Abbr.
Clin Exp Immunol
ISSN
0009-9104
Published
1979-04-00
Pages
46-53
Language
English
Region
England
NLM ID
0057202
PMCID
PMC1537690
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com