The sensitivity of liquid sensor, ion-selective microelectrodes to changes in temperature and solution level.

Pflugers Archiv : European journal of physiology ·Vol. 406 ·No. 6 ·1986-06-00 ·Pages 641-4

Vaughan-Jones RD, Kaila K

Abstract

Current procedures for the manufacture of ion-selective microelectrodes using liquid ion sensors result in two kinds of electrode, one with a short (10-100 micron) column of sensor at the tip and one with a long column (greater than 1 mm). We report here that the signal from a long-column microelectrode is very sensitive to small fluctuations in bath temperature and solution level when a recording is made above room temperature. This sensitivity is explained by the effects of temperature on the potentials developed at the interfaces between the ion sensor and the bordering aqueous solutions (the internal filling solution of the electrode and the test solution). If the temperature at the two interfaces is changed by different amounts, these interfacial potentials will also change by different amounts resulting in a change in the output of the electrode. Such an effect occurs for long-column electrodes because the column of sensor is usually not completely immersed in the heated test solution. Hence fluctuations in solution temperature and level will induce fluctuations in temperature along the column of sensor producing variations in the electrical signal from the electrode. In contrast, sensitivity to temperature and solution level is virtually absent in short-column microelectrodes since their column of sensor is fully immersed in the test solution and thereby at uniform temperature. In conclusion, in order to produce noise-free recordings of ion activities, the use of short-column microelectrodes is recommended for experiments performed above (or below) room temperature.

MeSH Terms
Electrophysiology/instrumentation Mathematics Microelectrodes Models, Theoretical Solutions Temperature
Chemicals
Solutions
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Vaughan-Jones R D
Kaila K
References (5)
5 references, click to expand
  1. A novel experimental chamber for single-cell voltage-clamp and patch-clamp applications with low electrical noise and excellent temperature and flow control.
    Pflugers Arch. 1986 May;406(5):536-9 PMID: 3714452
  2. Neutral carrier ion-selective microelectrodes for measurement of intracellular free calcium.
    Biochim Biophys Acta. 1980 Jul;599(2):623-38 PMID: 7407109
  3. Regulation of chloride in quiescent sheep-heart Purkinje fibres studied using intracellular chloride and pH-sensitive micro-electrodes.
    J Physiol. 1979 Oct;295:111-37 PMID: 42779
  4. Free calcium in sheep cardiac tissue and frog skeletal muscle measured with Ca2+-selective microelectrodes.
    Pflugers Arch. 1984 Sep;402(1):1-9 PMID: 6438604
  5. Intracellular measurements of ion activities.
    Annu Rev Biophys Bioeng. 1983;12:91-116 PMID: 6347046
Article Info
Journal
Pflugers Archiv : European journal of physiology
Abbr.
Pflugers Arch
ISSN
0031-6768
Published
1986-06-00
Pages
641-4
Language
English
Region
Germany
NLM ID
0154720
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com