Abstract
Studies were done to determine whether the minimal model approach and the glucose clamp measure equivalent indices of insulin action. Euglycemic glucose clamps (glucose, G: 85 mg/dl) were performed at two rates of insulin (I) infusion (15 and 40 mU/min per m2) in 10 subjects (body mass index, BMI, from 21 to 41 kg/m2). Insulin sensitivity index (SI) from clamps varied from 0.15 to 3.15 (mean: 1.87 +/- 0.36 X 10(-2) dl/[min per m2] per microU/ml), and declined linearly with increasing adiposity (versus BMI: r = -0.97; P less than 0.001). SI from modeling the modified frequently sampled intravenous tolerance test varied from 0.66 to 7.34 X 10(-4) min-1 per microU/ml, and was strongly correlated with SIP(clamp) (r = 0.89; P less than 0.001). SI and SIP(clamp) were similar (0.046 +/- 0.008 vs. 0.037 +/- 0.007 dl/min per microU/ml, P greater than 0.35); the relation had a slope not different from unity (1.05 P greater than 0.70) and passed through the origin (P greater than 0.40). However, on a period basis, SI exceeded SIP(clamp) slightly, due to inhibition of hepatic glucose output during the FSIGT, not included in SIP(clamp). These methods are equivalent for assessment of overall insulin sensitivity in normal and insulin-resistant nondiabetic subjects.
MeSH Terms
Adult
Blood Glucose/metabolism
Female
Glucose/administration & dosage
Glucose Tolerance Test
Humans
Insulin/blood,pharmacology
Insulin Resistance
Kinetics
Male
Middle Aged
Obesity/blood
Chemicals
Blood Glucose
Insulin
Glucose
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Bergman R N
Prager R
Volund A
Olefsky J M
References (27)
27 references, click to expand
-
Extreme insulin resistance in ataxia telangiectasia: defect in affinity of insulin receptors.
N Engl J Med. 1978 May 25;298(21):1164-71
PMID: 651946
-
Experimental validation of measurements of glucose turnover in nonsteady state.
Am J Physiol. 1978 Jan;234(1):E84-93
PMID: 623255
-
Quantitative estimation of insulin sensitivity.
Am J Physiol. 1979 Jun;236(6):E667-77
PMID: 443421
-
Glucose intolerance and aging: evidence for tissue insensitivity to insulin.
Diabetes. 1979 Dec;28(12):1095-101
PMID: 510806
-
Mechanisms of insulin resistance in human obesity: evidence for receptor and postreceptor defects.
J Clin Invest. 1980 Jun;65(6):1272-84
PMID: 6997333
-
Physiologic evaluation of factors controlling glucose tolerance in man: measurement of insulin sensitivity and beta-cell glucose sensitivity from the response to intravenous glucose.
J Clin Invest. 1981 Dec;68(6):1456-67
PMID: 7033284
-
Glucose storage deficiency as a cause of insulin resistance in obese-hyperinsulinaemic diabetes.
Int J Obes. 1982;6 Suppl 1:131-5
PMID: 6749718
-
In vivo deactivation of peripheral, hepatic, and pancreatic insulin action in man.
Diabetes. 1982 Oct;31(10):929-36
PMID: 6759226
-
Optimal segments: a method for smoothing tracer data to calculate metabolic fluxes.
Am J Physiol. 1983 May;244(5):E472-9
PMID: 6846533
-
Quantification of insulin secretion and in vivo insulin action in nonobese and moderately obese individuals with normal glucose tolerance.
Diabetes. 1983 Jul;32(7):600-4
PMID: 6345239
-
Use of glucose uptake and glucose clearance for the evaluation of insulin action in vivo.
Diabetes. 1984 Feb;33(2):184-91
PMID: 6363173
-
Presentation of a new method for specific measurement of in vivo insulin-stimulated glucose disposal in humans: comparison of this approach with the insulin clamp and minimal model techniques.
J Clin Endocrinol Metab. 1985 Apr;60(4):723-6
PMID: 3882738
-
Assessment of insulin sensitivity in vivo.
Endocr Rev. 1985 Winter;6(1):45-86
PMID: 3884329
-
Importance of glucose per se to intravenous glucose tolerance. Comparison of the minimal-model prediction with direct measurements.
Diabetes. 1985 Nov;34(11):1092-103
PMID: 2864297
-
Estimates of in vivo insulin action in humans: comparison of the insulin clamp and the minimal model techniques.
Horm Metab Res. 1985 Aug;17(8):406-9
PMID: 3902605
-
The insulin sensitivity index in nondiabetic man. Correlation between clamp-derived and IVGTT-derived values.
Diabetes. 1986 Mar;35(3):362-9
PMID: 3512346
-
MINMOD: a computer program to calculate insulin sensitivity and pancreatic responsivity from the frequently sampled intravenous glucose tolerance test.
Comput Methods Programs Biomed. 1986 Oct;23(2):113-22
PMID: 3640682
-
Interpretation of the rapid intravenous glucose tolerance test in normal individuals and in mild diabetes mellitus.
J Clin Invest. 1953 May;32(5):428-35
PMID: 13052703
-
Measurement of size and turnover rate of body glucose pool by the isotope dilution method.
Am J Physiol. 1956 Sep;187(1):15-24
PMID: 13362583
-
On the intravenous glucose tolerance test.
Acta Endocrinol (Copenh). 1957 Jul;25(3):312-34
PMID: 13443758
-
Influences of glucose loading and of injected insulin on hepatic glucose output.
Ann N Y Acad Sci. 1959 Sep 25;82:420-30
PMID: 13833973
-
Comparison of impedance to insulin-mediated glucose uptake in normal subjects and in subjects with latent diabetes.
J Clin Invest. 1970 Dec;49(12):2151-60
PMID: 5480843
-
Use of polyethylene glycol to separate free and antibody-bound peptide hormones in radioimmunoassays.
J Clin Endocrinol Metab. 1971 Nov;33(5):732-8
PMID: 5166455
-
Evaluation of insulin resistance in patients with primary hyperparathyroidism.
Proc Soc Exp Biol Med. 1975 Mar;148(3):942-5
PMID: 1129318
-
Demonstration of insulin resistance in untreated adult onset diabetic subjects with fasting hyperglycemia.
J Clin Invest. 1975 Mar;55(3):454-61
PMID: 1117064
-
A model of the kinetics of insulin in man.
J Clin Invest. 1974 May;53(5):1481-92
PMID: 4856884
-
Relationship between in vivo insulin resistance and decreased insulin receptors in obese man.
J Clin Endocrinol Metab. 1979 Mar;48(3):487-94
PMID: 429500