Home LiteratureArticle Details
PMID: 28250466 Published · ppublish English Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't

MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy.

Nature methods ·Vol. 14 ·No. 4 ·2017-00-00 ·Pages 331-332

Zheng SQ, Palovcak E, Armache JP, Verba KA, Cheng Y, Agard DA

Abstract

暂无摘要

MeSH Terms
Algorithms Archaeal Proteins/chemistry Cryoelectron Microscopy/methods Imaging, Three-Dimensional/methods Macromolecular Substances/chemistry Models, Molecular Motion Proteasome Endopeptidase Complex/chemistry TRPV Cation Channels/chemistry
Chemicals
Archaeal Proteins Macromolecular Substances TRPV Cation Channels Trpv1 protein, rat Proteasome Endopeptidase Complex
Authors & Affiliations
6 authors, click to expand affiliations / ORCID
Zheng Shawn Q
Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, California, USA. | Howard Hughes Medical Institute, University of California, San Francisco, San Francisco, California, USA.
Palovcak Eugene
Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, California, USA.
Armache Jean-Paul
Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, California, USA.
Verba Kliment A
Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, California, USA.
Cheng Yifan
Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, California, USA. | Howard Hughes Medical Institute, University of California, San Francisco, San Francisco, California, USA.
Agard David A
Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, California, USA. | Howard Hughes Medical Institute, University of California, San Francisco, San Francisco, California, USA.
References (8)
8 references, click to expand
  1. Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles.
    Elife. 2013 Feb 19;2:e00461 PMID: 23427024
  2. Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM.
    Nat Methods. 2013 Jun;10(6):584-90 PMID: 23644547
  3. Measuring the optimal exposure for single particle cryo-EM using a 2.6 Å reconstruction of rotavirus VP6.
    Elife. 2015 May 29;4:e06980 PMID: 26023829
  4. Alignment of cryo-EM movies of individual particles by optimization of image translations.
    J Struct Biol. 2015 Nov;192(2):188-95 PMID: 26296328
  5. Biochemistry. The resolution revolution.
    Science. 2014 Mar 28;343(6178):1443-4 PMID: 24675944
  6. Single-Particle Cryo-EM at Crystallographic Resolution.
    Cell. 2015 Apr 23;161(3):450-7 PMID: 25910205
  7. Structure of the TRPV1 ion channel determined by electron cryo-microscopy.
    Nature. 2013 Dec 5;504(7478):107-12 PMID: 24305160
  8. Beam-induced motion of vitrified specimen on holey carbon film.
    J Struct Biol. 2012 Mar;177(3):630-7 PMID: 22366277
Article Info
Journal
Nature methods
Abbr.
Nat Methods
ISSN
1548-7105
Published
2017-00-00
Epub
2017-00-27
Pages
331-332
Language
English
Region
United States
NLM ID
101215604
PMCID
PMC5494038
Subset
IM
Grants
NIGMS NIH HHS · T32 GM008284 · United States
NIGMS NIH HHS · R01 GM031627 · United States
NIGMS NIH HHS · P01 GM111126 · United States
NIGMS NIH HHS · P50 GM082250 · United States
NIGMS NIH HHS · R35 GM118099 · United States
NIGMS NIH HHS · R01 GM082893 · United States
NIGMS NIH HHS · R01 GM098672 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com