ELECTRIC IMPEDANCE OF THE SQUID GIANT AXON DURING ACTIVITY.

The Journal of general physiology ·Vol. 22 ·No. 5 ·1939-05-20 ·Pages 649-70

Cole KS, Curtis HJ

Abstract

Alternating current impedance measurements have been made over a wide frequency range on the giant axon from the stellar nerve of the squid, Loligo pealii, during the passage of a nerve impulse. The transverse impedance was measured between narrow electrodes on either side of the axon with a Wheatstone bridge having an amplifier and cathode ray oscillograph for detector. When the bridge was balanced, the resting axon gave a narrow line on the oscillograph screen as a sweep circuit moved the spot across. As an impulse passed between impedance electrodes after the axon had been stimulated at one end, the oscillograph line first broadened into a band, indicating a bridge unbalance, and then narrowed down to balance during recovery. From measurements made during the passage of the impulse and appropriate analysis, it was found that the membrane phase angle was unchanged, the membrane capacity decreased about 2 per cent, while the membrane conductance fell from a resting value of 1000 ohm cm.(2) to an average of 25 ohm cm.(2) The onset of the resistance change occurs somewhat after the start of the monophasic action potential, but coincides quite closely with the point of inflection on the rising phase, where the membrane current reverses in direction, corresponding to a decrease in the membrane electromotive force. This E.M.F. and the conductance are closely associated properties of the membrane, and their sudden changes constitute, or are due to, the activity which is responsible for the all-or-none law and the initiation and propagation of the nerve impulse. These results correspond to those previously found for Nitella and lead us to expect similar phenomena in other nerve fibers.

Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Cole K S
Department of Physiology, College of Physicians and Surgeons, Columbia University, New York, and the Marine Biological Laboratory, Woods Hole.
Curtis H J
References (2)
2 references, click to expand
  1. On a mechanical method of correcting photographic records obtained from the capillary electrometer.
    J Physiol. 1912 May 6;44(3):225-42 PMID: 16993124
  2. The relation between conduction velocity and the electrical resistance outside a nerve fibre.
    J Physiol. 1939 Jan 14;94(4):560-70 PMID: 16995066
Article Info
Journal
The Journal of general physiology
Abbr.
J Gen Physiol
ISSN
0022-1295
Published
1939-05-20
Pages
649-70
Language
English
Region
United States
NLM ID
2985110R
PMCID
PMC2142006
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com