Home LiteratureArticle Details
PMID: 16991116 Published · ppublish English Evaluation Study Journal Article Research Support, Non-U.S. Gov't

Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition.

Magnetic resonance in medicine ·Vol. 56 ·No. 5 ·2006-11-00 ·Pages 965-70

Mlynárik V, Gambarota G, Frenkel H, Gruetter R

Abstract

We developed a short-echo-time (TE) sequence for proton localized spectroscopy by combining a 1D add-subtract scheme with a doubly slice-selective spin-echo (SE) sequence. The sequence preserves the full magnetization available from the selected volume of interest (VOI). By reducing the number of radiofrequency (RF) pulses acting on transverse magnetization, we were able to minimize the TE to the level that is achievable with the stimulated echo acquisition mode (STEAM) technique, and also gained a twofold increase in sensitivity. The use of an adiabatic pulse in the add-subtract localization improved the efficiency of excitation in spatially inhomogeneous RF fields, which are frequently encountered at high magnetic fields. The localization performance and sensitivity gains of this method, which is termed SPin ECho, full Intensity Acquired Localized (SPECIAL) spectroscopy, were demonstrated in vivo in rat brains. In conjunction with spectroscopic imaging, a 2-microl spatial resolution was accomplished with a signal-to-noise ratio (SNR) above 30, which is usually sufficient for reliable quantification of a large number of metabolites (neurochemical profile).

MeSH Terms
Algorithms Animals Brain/metabolism Magnetic Resonance Spectroscopy/methods Male Nerve Tissue Proteins/analysis Neurotransmitter Agents/analysis Protons Rats Rats, Sprague-Dawley Reproducibility of Results Sensitivity and Specificity
Chemicals
Nerve Tissue Proteins Neurotransmitter Agents Protons
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Mlynárik Vladimír
Laboratory of Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
Gambarota Giulio
Frenkel Hanne
Gruetter Rolf
Article Info
Journal
Magnetic resonance in medicine
Abbr.
Magn Reson Med
ISSN
0740-3194
Published
2006-11-00
Pages
965-70
Language
English
Region
United States
NLM ID
8505245
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com