Home LiteratureArticle Details
PMID: 167662 Published · ppublish English Comparative Study Journal Article

Comparative study of four microporous filters for concentrating viruses from drinking water.

Applied microbiology ·Vol. 30 ·No. 1 ·1975-07-00 ·Pages 58-65

Jakubowski W, Hill WF, Clarke NA

Abstract

Four microporous virus-absorbent filter media for recovering low levels of virus from 380 liters of drinking water were compared. In addition two of the filter media were compared with 1,900 liters of drinking water. The filter media evaluated were MF nitrocellulose membranes (293 mm), AA Cox M-780 epoxy-fiberglass-asbestos disks (267 mm), K-27 yarn-wound fiberglass cartridges + AA Cox M-780 disks (127 mm), and Balston epoxy-fiberglass tubes (24.5 by 63.5 mm). The filters were used to concentrate seeded poliovirus from 380 liters of finished drinking water. Sodium thiosulfate was added to the drinking water to neutralize chlorine, and hydrochloric acid was added to adjust the pH to 3.5. Virus was eluted from the filters with glycine-NaOH buffer at pH 11.5. In terms of virus recovery efficiency, the filter media ranked Balston greater than Cox 267-mm greater than MF 293-mm congruent to K-27 + Cox 127-mm, but differences were slight. The Balston filters and holders were also superior to the other systems in terms of size, weight, cost, and handling factors. Experiments with 2- and 8-mum porosity Balston filters showed no statistically significant difference in virus recovery. Virus was readily detected by the Balston and the MF 293-mm systems at input levels of 12 to 22 PFU/1,900 liters. Preliminary experiments indicated that an elution pH lower than 11.5 may be satisfactory.

MeSH Terms
Asbestos Carcinoma, Squamous Cell Cell Line Cellulose Epoxy Resins Evaluation Studies as Topic Glass Humans Laryngeal Neoplasms Micropore Filters/standards Poliovirus/isolation & purification Viral Plaque Assay Water Microbiology Water Supply
Chemicals
Epoxy Resins Asbestos Cellulose
Authors & Affiliations
3 authors, click to expand affiliations / ORCID
Jakubowski W
Hill W F
Clarke N A
References (11)
11 references, click to expand
  1. Efficient filtration and sizing of viruses with membrane filters.
    J Virol. 1968 Jan;2(1):21-5 PMID: 4316012
  2. Virus in water. I. A preliminary study on a flow-through gauze sampler for recovering virus from waters.
    Appl Microbiol. 1971 Mar;21(3):405-10 PMID: 4324193
  3. Recovery of small quantities of viruses from clean waters on cellulose nitrate membrane filters.
    Appl Microbiol. 1971 Oct;22(4):608-14 PMID: 4331770
  4. Concentration of virus from water by electro-osmosis and forced-flow electrophoresis.
    Prep Biochem. 1971 Jan;1(1):77-89 PMID: 4334200
  5. Enterovirus concentration on cellulose membranes.
    Appl Microbiol. 1972 Mar;23(3):476-80 PMID: 4336660
  6. Recovery of poliovirus from turbid estuarine water on microporous filters by the use of celite.
    Appl Microbiol. 1974 Mar;27(3):506-12 PMID: 4363367
  7. Environmental factors influencing isolation of enteroviruses from polluted surface waters.
    Appl Microbiol. 1974 May;27(5):920-6 PMID: 4364463
  8. Apparatus for conditioning unlimited quantities of finished waters for enteric virus detection.
    Appl Microbiol. 1974 Jun;27(6):1177-8 PMID: 4364611
  9. Epoxy-fiberglass adsorbent for concentrating viruses from large volumes of potable water.
    Appl Microbiol. 1974 Sep;28(3):501-2 PMID: 4371783
  10. K-series centrifuges. I. Development of the K-II continuous-sample-flow-with-banding centrifuge system for vaccine purification.
    Anal Biochem. 1969 Dec;32(3):460-94 PMID: 5361400
  11. Concentration of enteroviruses from large volumes of water.
    Appl Microbiol. 1973 Oct;26(4):529-34 PMID: 16349972
Article Info
Journal
Applied microbiology
Abbr.
Appl Microbiol
ISSN
0003-6919
Published
1975-07-00
Pages
58-65
Language
English
Region
United States
NLM ID
7605802
PMCID
PMC187114
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com