主页 文献库文献详情
PMID: 16534405 已发表 · ppublish 英语

The trained observer better predicts daytime ABPM diastolic blood pressure in hypertensive patients than does an automated (Omron) device.

Blood pressure monitoring ·第 11 卷 ·第 2 期 ·2006-06-05

Graves(John W),Grossardt(Brandon R),Gullerud(Rachel E),Bailey(Kent R),Feldstein(Jeffrey)

摘要

Accurate blood pressure measurement is critical to successful clinical trials. Concerns about observer errors have led to the use of automated oscillometric devices without evidence that their performance is similar to that of trained observers. This study compares blood pressures obtained by trained observers and with an oscillometric device (Omron 705CP) to 24-h ambulatory blood pressure monitoring.,We performed a post-hoc analysis of 313 untreated hypertensive patients at the end of the washout phase of a Novartis hypertension trial. Patients had three seated trained observer mercury auscultatory blood pressure measurements followed by 24-h ambulatory blood pressure monitoring. The next day, the ambulatory blood pressure monitoring was removed and three seated readings were obtained with an Omron 705CP. Correlations for systolic blood pressure and diastolic blood pressure were obtained between daytime ambulatory blood pressure monitoring (0900 and 2100) and the two office methods. In addition, we investigated the degree of difference of trained observer and Omron measurements from ambulatory blood pressure monitoring.,For systolic blood pressure, the correlation with ambulatory blood pressure monitoring of the trained observer was significantly better than with that of the Omron 705CP (0.641 vs. 0.555, P=0.01). For diastolic blood pressure values, even greater disparity between the two office method correlations with ambulatory blood pressure monitoring was observed (trained observer=0.593 vs. Omron=0.319, P<0.0001). Both trained observer and Omron readings were consistently higher than ambulatory blood pressure monitoring for systolic blood pressure (P<0.0001) and diastolic blood pressure (P<0.0001). Omron measurements, however, deviated from ambulatory blood pressure monitoring more than those of the trained observer (P<0.0001 for systolic blood pressure and diastolic blood pressure).,For clinical trials using diastolic blood pressure targets, the Omron 705CP cannot replace the auscultatory blood pressure measurements of a trained observer. For systolic blood pressure, the Omron device and the trained observer had similar correlations with ambulatory blood pressure monitoring; however, both methods gave consistently higher systolic blood pressure values. Further study of oscillometric devices should be conducted before universally replacing auscultatory blood pressure determinations by trained observers in clinical trials.

文献信息
期刊
Blood pressure monitoring
期刊简称
Blood Press Monit
发表日期
2006-06-05
收录日期
2006-03-14
更新日期
2007-11-15
语言
英语
国家/地区
England
NLM ID
9606438
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: product@genelibs.com