Is the accuracy of blood pressure measuring devices underestimated at increasing blood pressure levels?

Blood pressure monitoring ·第 10 卷 ·第 5 期 ·2005-12-28

Braam(Richard L),Thien(Theo)

摘要

In validation studies reporting on the accuracy of blood pressure measuring devices (ambulatory and non-ambulatory systems), it is frequently stated that the accuracy of blood pressure devices seems to decrease at increasing blood pressure levels. This has been shown for several ambulatory devices in the past. Whether more recently validated devices are less accurate at increasing blood pressure levels is unknown, however.,We therefore retrospectively searched the literature for studies performed between 1993 and 2003, reporting on the accuracy of blood pressure measuring devices over different blood pressure levels. When needed, additional information from the authors was requested.,In total, 30 studies were selected. Of these, the studies reporting on the accuracy of 14 different ambulatory and nine different non-ambulatory devices were useful. For both ambulatory and non-ambulatory devices, accuracy appeared to decrease at increasing blood pressure levels. This was particularly shown for systolic blood pressure.,We speculate whether this finding is due to the oscillometric method of blood pressure measurement. Another explanation may exist, however. Blood pressure variability increases with higher blood pressure. Further, the British Hypertension Society protocol 1993 uses sequential measurements. This may be the reason that, owing to the increased blood pressure variability, the accuracy of most devices tends to decrease at higher blood pressure levels. Consequently, the accuracy of blood pressure measuring devices may be underestimated at higher blood pressure levels.,Currently used automated blood pressure measurement devices seem to be less accurate at increasing blood pressure levels. It is important to be aware of this phenomenon when treating hypertensive patients. The reported decrease in accuracy, however, may well be explained by the increasing blood pressure variability at increasing blood pressure and the use of sequential measurements. If this is the case, then the accuracy of these devices is perhaps underestimated.

文献信息
期刊
Blood pressure monitoring
期刊简称
Blood Press Monit
发表日期
2005-12-28
收录日期
2005-10-05
更新日期
2007-11-15
语言
英语
国家/地区
England
NLM ID
9606438
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: product@genelibs.com