Home LiteratureArticle Details
PMID: 1198395 Published · ppublish English Journal Article

Variability of routine pulmonary function tests.

Thorax ·Vol. 30 ·No. 5 ·1975-10-00 ·Pages 548-53

Hruby J, Butler J

Abstract

Pulmonary function tests sometimes indicate a progressive deterioration and at other times a 'stepwise' worsening which may be followed by improvement. Interpretation depends on the extent of random or diurnal variations in function. Routing pulmonary function tests (VC, FEV1, FRC, and airway resistance (Raw)) were repeatedly measured in normal subjects, patients with stable irreversible airways obstruction, and patients with stable restrictive disease. In all groups there was a significant (P less than 0.001) diurnal variation in Raw, with high values in the morning, low values at noon, and rising values in the evening. The midday Raw values were about 80% of the highest daily values. The considerable random and diurnal variability seen in all tests is reflected in the range of high and low values (% of mean individual response) in individuals. The largest variation in an individual between measurements taken at two different times was 81% in Raw (range: 40% above to 41% below the mean). There was less variation in FEV1 (29%), FRC (62%), and VC (30%). Thus the finding of a stepwise change in function could reflect its natrual variability. When repeated studies are done to assess progress or the effects of therapy on disease, there are many factors, including the time of day at which the tests are performed, which should be standardized as far as possible.

MeSH Terms
Air Pollution/analysis Airway Obstruction/diagnosis,physiopathology Airway Resistance Analysis of Variance Circadian Rhythm Female Forced Expiratory Volume Functional Residual Capacity Humans Lung/physiology Lung Diseases/diagnosis,physiopathology Lung Volume Measurements/methods Male Middle Aged Respiratory Function Tests Smoking Prevention Time Factors Vital Capacity
Authors & Affiliations
2 authors, click to expand affiliations / ORCID
Hruby J
Butler J
References (20)
20 references, click to expand
  1. Evaluation of "electronic" spirometers.
    N Engl J Med. 1973 Dec 13;289(24):1283-8 PMID: 4749547
  2. Measurement of airway variation and bronchial reactivity in normal and asthmatic subjects.
    Am Rev Respir Dis. 1967 Aug;96(2):266-74 PMID: 4951909
  3. [Daily rhythm of bronchial resistance in asthma].
    Respiration. 1968;25(5):405-20 PMID: 5673815
  4. Variation in respiratory function. Studies on patients and normal subjects.
    Arch Environ Health. 1966 Feb;12(2):217-26 PMID: 5901639
  5. Maximum breathing capacity and vital capacity in female children and adolescents.
    Pediatrics. 1953 Oct;12(4):341-52 PMID: 13099904
  6. Normal standards for lung volumes, intrapulmonary gas-mixing, and maximum breathing capacity.
    Thorax. 1954 Dec;9(4):313-25 PMID: 13226313
  7. The relationship between airway resistance, airway conductance and lung volume in subjects of different age and body size.
    J Clin Invest. 1958 Sep;37(9):1279-85 PMID: 13575526
  8. Changes during 24 hours in the lung function and histamine hyperreactivity of the bronchial tree in asthmatic and bronchitic patients.
    Int Arch Allergy Appl Immunol. 1962;20:93-101 PMID: 13926911
  9. Evaluation of methods used in detecting changes of airway resistance in man.
    Am Rev Respir Dis. 1963 Apr;87:529-37 PMID: 13931127
  10. Changes in forced expiratory volumes throughout the day.
    Br Med J. 1960 Feb 13;1(5171):462-4 PMID: 14416484
  11. Variability of the vital capacity of the normal human subject.
    J Physiol. 1949 Dec 15;110(1-2):76-82 PMID: 15406383
  12. The fate of the chronic bronchitic: a report of the ten-year follow-up in the Canadian Department of Veteran's Affairs coordinated study of chronic bronchitis. The J. Burns Amberson Lecture of the American Thoracic Society.
    Am Rev Respir Dis. 1973 Nov;108(5):1043-65 PMID: 4746563
  13. Long-term course of chronic obstructive pulmonary disease. A new view of the mode of functional deterioration.
    Am J Med. 1971 Oct;51(4):504-12 PMID: 5155771
  14. Observer variation in spirometry.
    Dis Chest. 1965 Sep;48(3):265-8 PMID: 5830640
  15. Variability of plethysmographic measurements of airways resistance in man.
    J Appl Physiol. 1967 Feb;22(2):383-9 PMID: 6017915
  16. A rapid plethysmographic method for measuring thoracic gas volume: a comparison with a nitrogen washout method for measuring functional residual capacity in normal subjects.
    J Clin Invest. 1956 Mar;35(3):322-6 PMID: 13295396
  17. The Veterans Administration-Army cooperative study of pulmonary function. I. Clinical spirometry in normal men.
    Am J Med. 1961 Feb;30:243-58 PMID: 13753281
  18. THE EFFECT OF NEBULIZED BRONCHODILATOR DELIVERED WITH AND WITHOUT IPPB ON VENTILATORY FUNCTION IN CHRONIC OBSTRUCTIVE EMPHYSEMA.
    Am Rev Respir Dis. 1965 Jan;91:13-20 PMID: 14259995
  19. Pulmonary function studies in children.
    Am J Dis Child. 1960 Aug;100:196-207 PMID: 14419191
  20. [Individual and general rhythm of diurnal variations in vital capacity].
    Acta Med Scand. 1950;137(6):441-51 PMID: 15432134
Article Info
Journal
Thorax
Abbr.
Thorax
ISSN
0040-6376
Published
1975-10-00
Pages
548-53
Language
English
Region
England
NLM ID
0417353
PMCID
PMC470324
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com