Analytical chemistry ·Vol. 73 ·No. 21 ·2001-11-01 ·Pages 5142-9

Zhang R, Sioma CS, Wang S, Regnier FE

Abstract

The goal of quantitative proteomics is to examine the expression levels of all of the proteins in a biological system and recognize those that change as a function of some stimulus. Quantification is now frequently based on derivatization of peptides with isotopically distinguishable labeling agents. This study examines the extent to which isotopic forms of peptides having the same amino acid sequence are resolved by reversed-phase chromatography and assesses the degree to which resolution of these isotopically different forms of a peptide impact quantification. Three derivatizing agents were examined, the do and d3 forms of N-acetoxysuccinimide, the do and d4 forms of succinic anhydride, and the do and d8 forms of the commercial ICAT reagent Peptide mixtures from control and experimental samples were derivatized individually, mixed, subjected to reversed-phase chromatography, and analyzed by ESI-MS. When partial resolution of the isotopic forms of a peptide occurs, the largest error in assessing the true isotope ratio in a sample occurs when sampling at the extremes of a peak. Early in the elution of a peak, the sample will be enriched in the deuterated species, whereas the opposite is true at the tailing edge of a peak. Acetylated peptides showed the lowest degree of separation. Resolution of the deuterated and nondeuterated forms in this case was 0.023. This amounts to slightly over a 1-s difference in their peak maxima and can cause a typical error of +/- 6% at the leading and tailing edges of a peak. In contrast, resolution of the deuterated and nondeuterated forms of the ICAT reagent were calculated to be 0.45. This means that in a peak of 1-min width (W1/2), the peak maxima will vary by approximately 30 s, and measurement errors of -83 and +500% can occur at the leading and tailing edges of a peak. It is concluded that resolution of isotopic forms of a peptide can cause substantial quantification errors in quantitative proteomics.

MeSH Terms
Angiotensin I/analysis Chemical Fractionation/methods Chromatography, High Pressure Liquid/methods Deuterium/metabolism Humans Isotope Labeling/methods Peptides/isolation & purification,metabolism Proteome/analysis,metabolism Spectrometry, Mass, Electrospray Ionization/methods
Chemicals
Peptides Proteome Angiotensin I Deuterium
Authors & Affiliations
4 authors, click to expand affiliations / ORCID
Zhang R
Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA.
Sioma C S
Wang S
Regnier F E
Article Info
Journal
Analytical chemistry
Abbr.
Anal Chem
ISSN
0003-2700
Published
2001-11-01
Pages
5142-9
Language
English
Region
United States
NLM ID
0370536
Subset
IM
Grants
NIGMS NIH HHS · GM 59996 · United States
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com