Home LiteratureArticle Details
PMID: 10545062 Published · ppublish English Comparative Study Journal Article

Different real-time PCR formats compared for the quantitative detection of human cytomegalovirus DNA.

Clinical chemistry ·Vol. 45 ·No. 11 ·1999-11-00 ·Pages 1932-7

Nitsche A, Steuer N, Schmidt CA, Landt O, Siegert W

Abstract

The aim of this study was to compare the ABI PRISM 7700 Sequence Detection System and the LightCycler to develop a quantitative real-time PCR assay for the detection of human cytomegalovirus (HCMV) DNA suitable for routine hospital application. We used one exonuclease probe and five different hybridization probe sets as sequence-specific fluorescence detection formats. For the exonuclease assay and two hybridization probe sets, reproducibility and the detection limit were determined. To keep the total assay time to a minimum, we gradually shortened individual reaction steps on both instruments. The exonuclease assay can be interchangeably performed on the 7700 and the LightCycler. No change of reaction conditions is required, except for the addition of bovine serum albumin to the LightCycler reaction. The shortest possible total assay time is 80 min for the ABI PRISM 7700 Sequence Detection System and 20 min for the LightCycler. When the LightCycler is used, the exonuclease probe can be replaced by a set of hybridization probes. All assays presented here detected HCMV DNA in a linear range from 10(1) to 10(7) HCMV genome equivalents/assay (r >0.995) with low intraassay (<5%) and interassay (<10%) variation. The ABI PRISM 7700 Sequence Detection System as well as the LightCycler are useful instruments for rapid and precise online PCR detection. Moreover, the two principles of fluorescence signal production allow HCMV quantification with the same accuracy.

MeSH Terms
Cytomegalovirus/genetics DNA, Viral/blood Endonucleases Fluorescence Humans Polymerase Chain Reaction/methods Reproducibility of Results Time Factors
Chemicals
DNA, Viral Endonucleases
Authors & Affiliations
5 authors, click to expand affiliations / ORCID
Nitsche A
Klinik für Innere Medizin m.S. Hämatologie und Onkologie, Charité-Campus Virchow Klinikum, Humboldt Universität, Augustenburger Platz 1, Forschungshaus 37 R 2.303, D-13353 Berlin, Germany. andreas.nitsche@charite.de
Steuer N
Schmidt C A
Landt O
Siegert W
Article Info
Journal
Clinical chemistry
Abbr.
Clin Chem
ISSN
0009-9147
Published
1999-11-00
Pages
1932-7
Language
English
Region
England
NLM ID
9421549
Subset
IM
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com